SUN Direct acting relief valve. T-10A. 95 Lpm

Direct-acting relief cartridges are normally closed, pressure-limiting valves used to protect hydraulic components from pressure transients. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to limit the pressure rise. These valves are smooth and quiet, essentially zero leak, dirt tolerant, immune to silting and are very fast.

  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits.
  • The seals on the adjust screw are exposed to system pressure which means this valve can only be adjusted when the pressure is removed. The setting procedure is; check the setting, remove the pressure, adjust the valve, check the new setting.
  • Valve is relatively insensitive to varying oil temperatures and oil borne contamination.
  • Select a spring range where the desired relief setting is approximately mid-range to high between the minimum and maximum pressure to ensure maximum valve repeatability.
  • Suitable for use in load holding applications.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Test pressure for the valve is 69 Bar.
  • Reseat meets or exceeds 90% of crack pressure at test setting. Settings lower than the test pressure may result in lower reseat percentages.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Artikelnummer:
RDDA-LBN

Förpackningsstorlek:
0 pcs

Minsta beställningskvantitet:
1 pcs
Ventilhus SUN T-10A G1/4
Artikelnummer: FAT
Sun Block T10A 3/8
Artikelnummer: FAU
Ventilhus SUN T-10A G1/2
Artikelnummer: FAV
Ventilhus SUN T-10A G1/2'' Stål
Artikelnummer: FAV/S
Ventilhus SUN T-10A G3/8''
Artikelnummer: FCU
Ventilhus SUN T-10A G1/2'' Stål
Artikelnummer: FEV/S
P-sats SUN T-10A, T-13A
Artikelnummer: 990-310-007
Brand Name
Sun Hydraulics

Cavity
T-10A

Contamination level max.
19/17/14 - ISO 4406

Flow rate nominal LMin
95 lpm

Material
Steel

Oil viscocity recommended
2,8 - 380 cSt

Pressure T max.
350 bar

Pressure max.
350 bar

Pressure setting max.
105 bar

Pressure setting min.
20 bar

Sealing material
NBR

Temperature max.
+110 °C

Temperature min.
-30 °C

Torque tightening
41 - 47 Nm
Förpackningsstorlek
0 pcs

Streckkod
5704334640592

Bruttovikt
0,17 Kg

Nettovikt
0,17 Kg

Ursprungsland

Intrastat artikelkod
84812010

Direct-acting relief cartridges are normally closed, pressure-limiting valves used to protect hydraulic components from pressure transients. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to limit the pressure rise. These valves are smooth and quiet, essentially zero leak, dirt tolerant, immune to silting and are very fast.

  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits.
  • The seals on the adjust screw are exposed to system pressure which means this valve can only be adjusted when the pressure is removed. The setting procedure is; check the setting, remove the pressure, adjust the valve, check the new setting.
  • Valve is relatively insensitive to varying oil temperatures and oil borne contamination.
  • Select a spring range where the desired relief setting is approximately mid-range to high between the minimum and maximum pressure to ensure maximum valve repeatability.
  • Suitable for use in load holding applications.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Test pressure for the valve is 69 Bar.
  • Reseat meets or exceeds 90% of crack pressure at test setting. Settings lower than the test pressure may result in lower reseat percentages.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.