Sun pressure regulating valve

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Recommended maximum inlet pressure is determined by the adjustment range. This valve configuration is tested with a 210 bar maximum differential between inlet and reduced pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Varenummer:
PBDB-LAN

Pakke str.:
0 pcs

Min. bestillingsenhed er:
1 pcs
EAU - Sun hus T11A R3/8
Partnumber: EAU
EAV - Sun hus T11A R1/2
Partnumber: EAV
EBA/M - Ventilhus SUN T-11A NG6
Partnumber: EBA/M
EBY - Sun sandwich ventilhus Cetop3
Partnumber: EBY
EBY/S - Ventilhus SUN T-11A x2 NG6 Stål
Partnumber: EBY/S
ECT - Sun hus T11A
Partnumber: ECT
ECT/S - Sun hus T11A stål
Partnumber: ECT/S
ECU - Sun hus T11A R3/8
Partnumber: ECU
Sun steel Block T11A 3/8
Partnumber: ECU/S
Sun valve block T11A R1/2 steel
Partnumber: ECV/S
Ventilhus SUN T-11A G1/4''
Partnumber: EFT
Ventilhus SUN T-11A G3/8'' Stål
Partnumber: EJU/S
Sun valve block T-11A Steel
Partnumber: X4B/S
YEV - Sun hus 2 x T11A R1/2
Partnumber: YEV
990-011-006 - Pakningssæt SUN T11-A Viton
Partnumber: 990-011-006
990-011-007 - Pakningssæt t/Sun ventil T11A Buna
Partnumber: 990-011-007
Cavity
T-11A

Flow Nominel
40 lpm

Forureningsgrad maks.
19/17/14 - ISO 4406

Materiale
Steel

Model kode
PBDBLAN

Mærke navn
Sun Hydraulics

Olieviskositet anbefalet
2,8 - 380 cSt

Pakningsmateriale
NBR

Temperatur maks.
+110 °C

Temperatur min.
-30 °C

Tilspændingsmoment
41 - 47 Nm

Tryk maks.
350 bar

Trykindstilling maks.
210 bar

Trykindstilling min.
7 bar
Package size
0 pcs

Barcode
5704295493152

Gross weight
0,17 Kg

Net weight
0,17 Kg

Country of origin

Intrastat code
84812010

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Recommended maximum inlet pressure is determined by the adjustment range. This valve configuration is tested with a 210 bar maximum differential between inlet and reduced pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.