Tryckbegränsningsventil SUN T-8A Propstyrd

This 2-port, pilot-stage, direct-acting relief cartridge is an electro-proportionally controlled, pressure regulating valve. The proportional control allows for infinite, step-less adjustability within the selected pressure range. When the pressure at port 1 (inlet) is sufficient to overcome the solenoid forces, as determined by the analog input signal, the poppet lifts and allows flow from port 1 to port 2 (outlet). This pilot control cartridge utilizes the T-8A cavity so it can be used in conjunction with Sun's main stage, pressure control elements.

  • Varying the analog input signal to the proportional solenoid provides a step-less control of pressure.
  • This electro-proportional cartridge utilizes the Sun T-8A, 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-port pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
  • All pressure ranges will drop to a setting of 0 with no analog input signal. The pressure ranges indicate the valve's area of acceptable performance.
  • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • NOTE: There is no upper limit to the pressure setting when using the M control. The more force you exert on the manual override, the higher the resulting pressure.
  • High pilot capacity allows for operation of larger size main stage elements.
  • Capable of operating with pressures up to 350 Bar.
  • Low leakage levels in the closed position. (Reseat occurs at 85% of cracking pressure.)
  • Coils are interchangeable with Sun's other full flow, solenoid operated valves and can be mounted on the tube in either direction.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Partnumber:
RBAP-MWN

Package size:
0 pcs

Min. order quantity is:
1 pcs
770212 - SUN 12 volt spole. ISO/DIN
Partnumber: 770212
24 VDC coil with ISO/DIN 43650 connector with TVS Diode
Partnumber: 770224
COIL med Deutsch DT04-2P
Partnumber: 770924
SUN Controller XMD 9-32VDC
Partnumber: XMD-01
990-008-007 - Pakningssæt SUN Serie P T-8A
Partnumber: 990-008-007
990-770-006 - Pakningssæt SUN til spolerør og møtrikker
Partnumber: 990-770-006
Cavity
T-8A

Flow Nominel
1 lpm

Forureningsgrad maks.
15/13/11 - ISO 4406

Materiale
Steel

Model kode
RBAPMWN

Mærke navn
Sun Hydraulics

Olieviskositet anbefalet
2,8 - 380 cSt

Pakningsmateriale
NBR

Temperatur maks.
+110 °C

Temperatur min.
-30 °C

Tilspændingsmoment
27 - 33 Nm

Tryk maks.
350 bar

Trykindstilling maks.
350 bar

Trykindstilling min.
35 bar
Package size
0 pcs

Barcode
5715803521946

Gross weight
Kg

Net weight
Kg

Country of origin
usa

This 2-port, pilot-stage, direct-acting relief cartridge is an electro-proportionally controlled, pressure regulating valve. The proportional control allows for infinite, step-less adjustability within the selected pressure range. When the pressure at port 1 (inlet) is sufficient to overcome the solenoid forces, as determined by the analog input signal, the poppet lifts and allows flow from port 1 to port 2 (outlet). This pilot control cartridge utilizes the T-8A cavity so it can be used in conjunction with Sun's main stage, pressure control elements.

  • Varying the analog input signal to the proportional solenoid provides a step-less control of pressure.
  • This electro-proportional cartridge utilizes the Sun T-8A, 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-port pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
  • All pressure ranges will drop to a setting of 0 with no analog input signal. The pressure ranges indicate the valve's area of acceptable performance.
  • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • NOTE: There is no upper limit to the pressure setting when using the M control. The more force you exert on the manual override, the higher the resulting pressure.
  • High pilot capacity allows for operation of larger size main stage elements.
  • Capable of operating with pressures up to 350 Bar.
  • Low leakage levels in the closed position. (Reseat occurs at 85% of cracking pressure.)
  • Coils are interchangeable with Sun's other full flow, solenoid operated valves and can be mounted on the tube in either direction.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.