2-way, 2 position, normally closed, high pressure. Free flow in both directions when solenoid is energized.
De- energized the spring holds the pilot against its seat. Pressure on the side port behind the poppet holds it firmly closed. Pressure on the nose port lifts and opens the poppet.
Energized the pilot is pulled by the armature lifting it off its seat. Side port pressure creates pilot flow across the poppet and a pressure imbalance which allows it to lift.
Features
Symmetrical coil can be reversed without affecting performance.
2-way, 2 position, normally closed, high pressure. Free flow in both directions when solenoid is energized.
De- energized the spring holds the pilot against its seat. Pressure on the side port behind the poppet holds it firmly closed. Pressure on the nose port lifts and opens the poppet.
Energized the pilot is pulled by the armature lifting it off its seat. Side port pressure creates pilot flow across the poppet and a pressure imbalance which allows it to lift.
Features
Symmetrical coil can be reversed without affecting performance.