SOLENOID VALVE POPPET SVP10-NOR-00-00-B-F-00

This is a 2-way, 2-position, poppet type, pilot operated, normally open solenoid valve. When de-energized, fl­ow can take place from port 2 to 1 and from 1 to 2. In its energized condition, ­flow can take place from port 1 to 2 but is blocked in the other direction. Leakage is kept to a minimum due to the poppet design. Some models have the option of a filter around port 2, and these come standard with a push pin manual override.

These valves can be used to hold loads in position when energized, interrupt a pressure line where ­ow normally passes in both directions, or bypass excess oil to tank in a fail-safe way.

Partnumber:
805338719

Package size:
0 pcs

Min. order quantity is:
1 pcs
Coil H16-24D-29W-FL-DB
Partnumber: 11039515
Coil H16-12D-29W-DE
Partnumber: 11039516
Coil H16-24D-29W-DE
Partnumber: 11039517
Coil H16-12D-29W-DE-DB
Partnumber: 11039518
Coil H16-24D-29W-DE-DB
Partnumber: 11039519
Dubbelt parallellt ventilhus 1/2" DPL10-2-4B
Partnumber: 11137221
Housing SDC10-2-S3B steel 3/8
Partnumber: 11143048
Ventilhus SDC10-2-S4B stål 1/2" port
Partnumber: 11143049
Housing SDC10-2--LG14B (1/2)
Partnumber: 922514110
Housing SDC10-2--LG24B (1/2)
Partnumber: 922514210
HOUSING, SDC10-2-DG3B (3/8) SDC10-2-DG3B (3/8)
Partnumber: 922516910
HOUSING, SDC10-2-DG4B (1/2) SDC10-2-DG4B (1/2)
Partnumber: 922517010
SEAL KIT SDC 10-2 B #
Partnumber: 354000719
Activation
Solenoid

Brand Name
Danfoss

Cavity
SDC10-2

Contamination level max.
20/18/14 - ISO 4406

Filter built-in
Yes

Flow rate nominal LMin
80 lpm

Manual operated
No

Model code
SVP10-NOR-00-00-B-F-00

Number of ways/positions
2/2

Oil viscocity recommended
12 - 54 cSt

Pressure max.
230 bar

Sealing material
NBR

Solenoidtype
M16

Temperature max.
+100 °C

Temperature min.
-40 °C

Torque tightening
45 - 50 Nm

Valve type
NO - Normally open
Package size
0 pcs

Barcode
5704334372547

Gross weight
0,20 Kg

Net weight
0,20 Kg

Country of origin

Intrastat code
84812010

This is a 2-way, 2-position, poppet type, pilot operated, normally open solenoid valve. When de-energized, fl­ow can take place from port 2 to 1 and from 1 to 2. In its energized condition, ­flow can take place from port 1 to 2 but is blocked in the other direction. Leakage is kept to a minimum due to the poppet design. Some models have the option of a filter around port 2, and these come standard with a push pin manual override.

These valves can be used to hold loads in position when energized, interrupt a pressure line where ­ow normally passes in both directions, or bypass excess oil to tank in a fail-safe way.