Sequence valve with check valve 35-210 bar - 60 l/min

Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Suitable for use in load holding applications.
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Artikelnummer:
SCCA-LAN

Förpackningsstorlek:
0 pcs

Minsta beställningskvantitet:
1 pcs
Ventilhus SUN T-11A NG6
Partnumber: EBA/M
Sun sandwich ventilhus Cetop3
Partnumber: EBY
Ventilhus SUN T-11A x2 NG6 Stål
Partnumber: EBY/S
Ventilhus SUN T-11A G1/4''
Partnumber: ECT
Sun hus T11A stål
Partnumber: ECT/S
Sun hus T11A R3/8
Partnumber: ECU
Sun stålhus T11A R3/8
Partnumber: ECU/S
Sun hus T11A R1/2 stål
Partnumber: ECV/S
Ventilhus SUN T-11A G1/4''
Partnumber: EFT
Ventilhus SUN T-11A G3/8'' Stål
Partnumber: EJU/S
Sun valve block T-11A Steel
Partnumber: X4B/S
Sun Block 2 x T11A 3/8
Partnumber: YEU
Sun Housing T-11A R3/8
Partnumber: YEU/S
Sun Block 2 x T11A 1/2
Partnumber: YEV
Sun Housing 2x T-11A R1/2
Partnumber: YEV/S
Cavity
T-11A

Flow Nominel
60 lpm

Forureningsgrad maks.
19/17/14 - ISO 4406

Materiale
Steel

Model kode
SCCALAN

Mærke navn
Sun Hydraulics

Olieviskositet anbefalet
2,8 - 380 cSt

Pakningsmateriale
NBR

Temperatur maks.
+110 °C

Temperatur min.
-30 °C

Tilspændingsmoment
41 - 47 Nm

Tryk maks.
350 bar

Trykindstilling maks.
210 bar

Trykindstilling min.
35 bar
Package size
0 pcs

Barcode
5704334595915

Gross weight
0,22 Kg

Net weight
0,22 Kg

Country of origin

Intrastat code
84812010

Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Suitable for use in load holding applications.
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.