Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All spring ranges are tested for correct operation with 350 Bar inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 Bar.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Artikelnummer:
PRDB-LDN

Förpackningsstorlek:
0 pcs

Minsta beställningskvantitet:
1 pcs
Ventilhus SUN T-11Ax2
Varenummer: YEV
Ventilhus SUN T-11Ax2 Stål
Varenummer: YEV/S
Cavity
T-11A

Flow Nominel
40 lpm

Forureningsgrad maks.
19/17/14 - ISO 4406

Materiale
Steel

Mærke navn
Sun Hydraulics

Olieviskositet anbefalet
2,8 - 380 cSt

Pakningsmateriale
NBR

Temperatur maks.
+110 °C

Temperatur min.
-30 °C

Tilspændingsmoment
41 - 47 Nm

Tryk T maks.
350 bar

Tryk maks.
350 bar

Trykindstilling maks.
55 bar

Trykindstilling min.
1.7 bar
Pakke str.
0 pcs

Stregkode
5704295778198

Brutto vægt
0,21 Kg

Netto vægt
0,21 Kg

Oprindelsesland

Intrastat varekode
84812010

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All spring ranges are tested for correct operation with 350 Bar inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 Bar.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.