SUN direct actin pressure reducing valve

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All spring ranges are tested for correct operation with 350 Bar inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 Bar.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Varenummer:
PRDB-LDN

Pakke str.:
0 pcs

Min. bestillingsenhed er:
1 pcs
EAU - Ventilhus SUN T-11A 90gr
Artikelnummer: EAU
Sun Block steel, T11A 3/8
Artikelnummer: EAU/S
Sun Block T11A 1/2
Artikelnummer: EAV
Ventilhus SUN T-11A NG6
Artikelnummer: EBA/M
EBY - Sun sandwich ventilhus Cetop3
Artikelnummer: EBY
EBY/S - Ventilhus SUN T-11A x2 NG6 Stål
Artikelnummer: EBY/S
Sun Block T11A
Artikelnummer: ECT
ECT/S - Sun hus T11A stål
Artikelnummer: ECT/S
Sun Block T11A 3/8
Artikelnummer: ECU
ECU/S - Sun stålhus T11A R3/8
Artikelnummer: ECU/S
ECV/S - Sun hus T11A R1/2 stål
Artikelnummer: ECV/S
EFT - Ventilhus SUN T-11A G1/4''
Artikelnummer: EFT
Ventilhus SUN T-11A G3/8'' Stål
Artikelnummer: EJU/S
P-sats SUN T11-A, Viton
Artikelnummer: 990-011-006
990-011-007 - Pakningssæt t/Sun ventil T11A Buna
Artikelnummer: 990-011-007
Brand Name
Sun Hydraulics

Cavity
T-11A

Contamination level max.
19/17/14 - ISO 4406

Flow rate nominal LMin
40 lpm

Material
Steel

Oil viscocity recommended
2,8 - 380 cSt

Pressure T max.
350 bar

Pressure max.
350 bar

Pressure setting max.
55 bar

Pressure setting min.
1.7 bar

Sealing material
NBR

Temperature max.
+110 °C

Temperature min.
-30 °C

Torque tightening
41 - 47 Nm
Förpackningsstorlek
0 pcs

Streckkod
5704295778198

Bruttovikt
0,21 Kg

Nettovikt
0,21 Kg

Ursprungsland

Intrastat artikelkod
84812010

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All spring ranges are tested for correct operation with 350 Bar inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 Bar.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.