Sequence valve with check valve 35-210 bar - 60 l/min

Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Suitable for use in load holding applications.
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Varenummer:
SCCA-LAN

Pakke str.:
0 pcs

Min. bestillingsenhed er:
1 pcs
Ventilhus SUN T-11A 90gr
Artikelnummer: EAU
Ventilhus SUN T-11A G3/8'' Stål
Artikelnummer: EAU/S
Ventilhus SUN T-11A 90gr
Artikelnummer: EAV
Ventilhus SUN T-11A NG6
Artikelnummer: EBA
Pakningssæt SUN T11-A Viton
Artikelnummer: 990-011-006
P-sats SUN T-11A Nitril
Artikelnummer: 990-011-007
Cavity
T-11A

Flow Nominel
60 lpm

Forureningsgrad maks.
19/17/14 - ISO 4406

Materiale
Steel

Model kode
SCCALAN

Mærke navn
Sun Hydraulics

Olieviskositet anbefalet
2,8 - 380 cSt

Pakningsmateriale
NBR

Temperatur maks.
+110 °C

Temperatur min.
-30 °C

Tilspændingsmoment
41 - 47 Nm

Tryk maks.
350 bar

Trykindstilling maks.
210 bar

Trykindstilling min.
35 bar
Förpackningsstorlek
0 pcs

Streckkod
5704334595915

Bruttovikt
0,22 Kg

Nettovikt
0,22 Kg

Ursprungsland

Intrastat artikelkod
84812010

Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Suitable for use in load holding applications.
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.