Sun pressure regulating valve

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Recommended maximum inlet pressure is determined by the adjustment range. This valve configuration is tested with a 210 bar maximum differential between inlet and reduced pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Varenummer:
PBDB-LBN

Pakke str.:
1 pcs

Min. bestillingsenhed er:
1 pcs
Sun Block T11A 3/8
Varenummer: EAU
Sun Block steel, T11A 3/8
Varenummer: EAU/S
Sun Block T11A 1/2
Varenummer: EAV
Sun sandwich valve Block Ceto
Varenummer: EBA
Ventilhus SUN T-11A NG6
Varenummer: EBA/M
Sun sandwich valve Block cetop
Varenummer: EBY
Ventilhus SUN T-11A x2 NG6 Stål
Varenummer: EBY/S
Sun Block T11A
Varenummer: ECT
Sun Block T11A steel
Varenummer: ECT/S
Sun hus T11A R3/8
Varenummer: ECU
Sun steel Block T11A 3/8
Varenummer: ECU/S
Sun Block T11A 1/2
Varenummer: ECV
Sun valve block T11A R1/2 steel
Varenummer: ECV/S
Ventilhus SUN T-11A G1/4''
Varenummer: EFT
Ventilhus SUN T-11A G3/8'' Stål
Varenummer: EJU/S
Sun ventilhus T-11A Stål
Varenummer: X4B/S
Ventilhus SUN T-11A dubbel
Varenummer: YEU
Ventilhus SUN T-11A dubbel stål
Varenummer: YEU/S
Sun hus 2 x T11A R1/2
Varenummer: YEV
Ventilhus SUN T-11Ax2 Stål
Varenummer: YEV/S
P-sats SUN T11-A, Viton
Varenummer: 990-011-006
Seal kit t/Sun valve T11A Buna
Varenummer: 990-011-007
Brand Name
Sun Hydraulics

Cavity
T-11A

Contamination level max.
19/17/14 - ISO 4406

Flow rate nominal LMin
40 lpm

Material
Steel

Oil viscocity recommended
2,8 - 380 cSt

Pressure max.
350 bar

Pressure setting max.
105 bar

Pressure setting min.
3.5 bar

Sealing material
NBR

Temperature max.
+110 °C

Temperature min.
-30 °C

Torque tightening
41 - 47 Nm
Pakke str.
1 pcs

Stregkode
5704334520214

Brutto vægt
0,15 Kg

Netto vægt
0,15 Kg

Oprindelsesland

Intrastat varekode
84812010

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Recommended maximum inlet pressure is determined by the adjustment range. This valve configuration is tested with a 210 bar maximum differential between inlet and reduced pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.