Sequence valve 240l/min 350bar

Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Suitable for use in load holding applications.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Partnumber:
SCGALDN

Package size:
0 pcs

Min. order quantity is:
1 pcs
Ventilhus SUN T-17A NG16 dubbel
Varenummer: BKY
Ventilhus SUN T-17A dubbel
Varenummer: HCW
Sun Block T17A 1
Varenummer: HCX
P-sats SUN T-17A viton
Varenummer: 990-017-006
P-sats SUN T-17A nitril
Varenummer: 990-017-007
Flödeshastighet nominell LMin
240 lpm

Föroreningsgrad max.
19/17/14 - ISO 4406

Kavitet
T-17A

Modell kod
SCGALDN

Märke namn
Sun Hydraulics

Oljeviskositet rekommanderad
2,8 - 380 cSt

Packningsmaterial
NBR

Temperatur max.
+110 °C

Temperatur min.
-30 °C

Tillverkningsmaterial
Steel

Tryck max.
350 bar

Tryckinställning max.
55 bar

Tryckinställning min.
14 bar

Åtdragning moment
203 - 217 Nm
Pakke str.
0 pcs

Stregkode
5704334858645

Brutto vægt
0,30 Kg

Netto vægt
0,30 Kg

Oprindelsesland
usa

Intrastat varekode
84812010

Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Suitable for use in load holding applications.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.