Sun load control valve 4,5:1

4.5:1 pilot ratio, standard capacity counterbalance valve

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • This valve does not have positive seals on the pilot section and will pass up to 32 cc/min.@70 bar between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Varenummer:
CBEG-LJN

Pakke str.:
0 pcs

Min. bestillingsenhed er:
1 pcs
Ventilhus SUN T-2A NG10 B-B Alu. 210bar
Varenummer: BBB
Ventilhus SUN T-2A NG10
Varenummer: BBY
Ventilhus SUN T-2A G3/4
Varenummer: BCW
Pakningssæt SUN T-2A nitril
Varenummer: 990-202-007
Cavity
T-2A

Flow Nominel
120 lpm

Forureningsgrad maks.
19/17/14 - ISO 4406

Materiale
Steel

Mærke navn
Sun Hydraulics

Olieviskositet anbefalet
2,8 - 380 cSt

Pakningsmateriale
NBR

Pilotforhold
4,5:1

Temperatur maks.
+110 °C

Temperatur min.
-30 °C

Tilspændingsmoment
61 - 68 Nm

Tryk maks.
350 bar

Trykindstilling maks.
350 bar

Trykindstilling min.
140 bar
Pakke str.
0 pcs

Stregkode
5704295216522

Brutto vægt
0,30 Kg

Netto vægt
0,30 Kg

Oprindelsesland

Intrastat varekode
84812010

4.5:1 pilot ratio, standard capacity counterbalance valve

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • This valve does not have positive seals on the pilot section and will pass up to 32 cc/min.@70 bar between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.