Press. Reducing valve 40l/m 30-140bar PPRC 06-EN-2-00-XXX

This is a normally open, pilot operated pressure reducing valve. Port 2 is open to port 1 until the setting is reached at which time the valve throttles the outlet ­flow limiting the pressure. Port 3 is a drain port only, as the valve does not contain a relief function. This valve is ideal for stable and precise control of a secondary pressure within a circuit.

Artikelnummer:
810120519

Förpackningsstorlek:
1 st

Minsta beställningskvantitet:
1 st
Ventilhus Comatrol NCS 06/3 SE 1/2
Artikelnummer: 922500713
Ventilhus Comatrol NCS 06/3 SE 3/8 (D)
Artikelnummer: 922500813
Ventilhus Comatrol NCS 06/3 SI 3/8
Artikelnummer: 922501113
Ventilhus Comatrol NCS06/3--SI 1/2
Artikelnummer: 922501213
Housing NCS06/3-DL 3/8
Artikelnummer: 922501313
Ventilhus Comatrol NCS06/3--DL 1/2
Artikelnummer: 922501413
Ventilhus Comatrol NCS06/3-SEL 3/8
Artikelnummer: 922503913
SEAL KIT NCS 06 3 VIE VITON #
Artikelnummer: 230000110
Brand Name
Danfoss

Cavity
NCS06/3

Contamination level max.
20/18/14 - ISO 4406

Flow rate nominal LMin
40 lpm

Key size
27 mm

Material
Steel

Model code
PPRC06-EN-2-00-XXX

Oil viscocity recommended
12 - 54 cSt

Pressure max.
315 bar

Pressure setting max.
140 bar

Pressure setting min.
30 bar

Sealing material
NBR

Temperature max.
+50 °C

Temperature min.
-20 °C

Torque tightening
45 - 50 Nm
Förpackningsstorlek
1 st

Streckkod
374702

Bruttovikt
0,15 Kg

Nettovikt
0,15 Kg

Ursprungsland
ITA

Intrastat artikelkod
84812010

This is a normally open, pilot operated pressure reducing valve. Port 2 is open to port 1 until the setting is reached at which time the valve throttles the outlet ­flow limiting the pressure. Port 3 is a drain port only, as the valve does not contain a relief function. This valve is ideal for stable and precise control of a secondary pressure within a circuit.