C.B. Valve 60l/m 60-150bar 3:1 CB10 HV-2-A-1-E-XXX-B-00

CB10-HV, Hydraulic Vent Valve.

Operation

CB10-HV: Counterbalance valve, 10-size, hydraulic vent. This valve is 3-ported, externally piloted and low leakage. The check section allows free flow from the directional valve (port 2) to the load (port 1), while normally blocking flow from port 1 to port 2. Reverse flow is blocked until pilot pressure is applied at port 3. When the load pressure at port 1 rises above the pressure setting, the integral relief valve is activated, and pressure is relieved from port 1 to port 2.

 

Applications

Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center.

Varenummer:
860103219

Pakke str.:
0 pcs

Min. bestillingsenhed er:
1 pcs
Valve Housing f.Orbital Motor MM-OMP/OMR-00-CB10-4B
Partnumber: 11026314
Ventilhus till Orbital Motor MM-DH/DS-LS-CB10-4B
Partnumber: 11026320
Ventilhus SDC10-3S-SE4B 1/2
Partnumber: 922517410
Ventilhus DCB10-3S-SE-3B 3/8
Partnumber: 922518510
Pakningssæt CB 10
Partnumber: 230001020
Cavity
SDC10-3S

Flow Nominel
60 lpm

Forureningsgrad maks.
20/18/14 - ISO 4406

Model kode
CB10-HV-2-A-1-E-XXX-B-00

Mærke navn
Danfoss

Olieviskositet anbefalet
12 - 54 cSt

Pakningsmateriale
NBR

Pilotforhold
3:1

Tilspændingsmoment
45 - 50 Nm

Tryk maks.
350 bar

Trykindstilling maks.
150 bar

Trykindstilling min.
60 bar
Package size
0 pcs

Barcode
5704334468257

Gross weight
0,22 Kg

Net weight
0,22 Kg

Country of origin
ITA

Intrastat code
84812010

CB10-HV, Hydraulic Vent Valve.

Operation

CB10-HV: Counterbalance valve, 10-size, hydraulic vent. This valve is 3-ported, externally piloted and low leakage. The check section allows free flow from the directional valve (port 2) to the load (port 1), while normally blocking flow from port 1 to port 2. Reverse flow is blocked until pilot pressure is applied at port 3. When the load pressure at port 1 rises above the pressure setting, the integral relief valve is activated, and pressure is relieved from port 1 to port 2.

 

Applications

Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center.