VCB06-EN-2-B-00 load control valve

VCB 06-EN, Overcenter Valve, Standard, Differential Area, Internal Drain, Port 1 Pilot

This is a differential area overcenter valve, which is a pilot assisted relief with a free flow check. With the relief valve set at around 1.3 times the maximum load induced pressure, the valve will prevent flow from taking place between ports 3 and 2. When pilot pressure is applied to port 1, the valve will meter the flow from port 3 to 2 compensating for any change in pilot pressure due to over-running or unstable loads. Free flow takes place from port 2 to port 3 through the check portion of the valve.

These valves are ideal in most applications bringing stability, load holding, and hose failure protection when the valve is mounted onto or into the actuator. The spring chamber is connected to the valve port 2, so any back pressure will increase the pilot pressure required to keep the valve open and the pressure at which the valve will open as a relief valve.

Partnumber:
820158929

Package size:
0 pcs

Min. order quantity is:
1 pcs
LINE BODY, NCS 06/3 SE 1/2 NCS06/3--SE 1/2
Varenummer: 922500713
LINE BODY, NCS 06/3 SE 3/8 (D) NCS06/3-SE 3/8 (D)
Varenummer: 922500813
LINE BODY, NCS 06/3 SI 3/8 NCS06/3--SI 3/8
Varenummer: 922501113
Housing NCS06/3--SI 1/2
Varenummer: 922501213
Housing NCS06/3-DL 3/8
Varenummer: 922501313
Housing NCS06/3--DL 1/2
Varenummer: 922501413
Housing NCS06/3-SEL 3/8
Varenummer: 922503913
SEAL KIT NCS 06 3 VIE VITON #
Varenummer: 230000110
Cavity
NCS06/3

Flow Nominel
60 lpm

Forureningsgrad maks.
20/18/14 - ISO 4406

Model kode
VCB06-EN-2-B-00

Mærke navn
Danfoss

Olieviskositet anbefalet
12 - 54 cSt

Pilotforhold
4,1:1

Tilspændingsmoment
44 - 50 Nm

Tryk maks.
350 bar

Trykindstilling maks.
210 bar

Trykindstilling min.
70 bar
Pakke str.
0 pcs

Stregkode
5704334322368

Brutto vægt
0,20 Kg

Netto vægt
0,20 Kg

Oprindelsesland

Intrastat varekode
84812010

VCB 06-EN, Overcenter Valve, Standard, Differential Area, Internal Drain, Port 1 Pilot

This is a differential area overcenter valve, which is a pilot assisted relief with a free flow check. With the relief valve set at around 1.3 times the maximum load induced pressure, the valve will prevent flow from taking place between ports 3 and 2. When pilot pressure is applied to port 1, the valve will meter the flow from port 3 to 2 compensating for any change in pilot pressure due to over-running or unstable loads. Free flow takes place from port 2 to port 3 through the check portion of the valve.

These valves are ideal in most applications bringing stability, load holding, and hose failure protection when the valve is mounted onto or into the actuator. The spring chamber is connected to the valve port 2, so any back pressure will increase the pilot pressure required to keep the valve open and the pressure at which the valve will open as a relief valve.