Sun pilot operated relief valv

Ventable, pilot-operated, balanced piston relief cartridges are normally closed pressure regulating valves. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to regulate the pressure. They provide a vent port (port 3) that connects between the main piston and pilot stage to provide for remote control by other pilot or 2-way valves. These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast.

  • A remote pilot relief on port 3 (vent) will control the valve below its own setting.
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. If used in cross port relief circuits, consider spool leakage.
  • Main stage orifice is protected by a 150-micron stainless steel screen.
  • Not suitable for use in load holding applications due to spool leakage.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Partnumber:
RVCA-LAN

Package size:
1 st

Min. order quantity is:
1 st
Cavity
T-11A

Flow Nominel
60 lpm

Forureningsgrad maks.
19/17/14 - ISO 4406

Materiale
Steel

Model kode
RVCALAN

Mærke navn
Sun Hydraulics

Olieviskositet anbefalet
2,8 - 380 cSt

Pakningsmateriale
NBR

Temperatur maks.
+110 °C

Temperatur min.
-30 °C

Tilspændingsmoment
41 - 47 Nm

Tryk T maks.
350 bar

Tryk maks.
350 bar

Trykindstilling maks.
210 bar

Trykindstilling min.
7 bar
Package size
1 st

Barcode
238041

Gross weight
0,17 Kg

Net weight
0,17 Kg

Country of origin

Intrastat code
84812010

Ventable, pilot-operated, balanced piston relief cartridges are normally closed pressure regulating valves. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to regulate the pressure. They provide a vent port (port 3) that connects between the main piston and pilot stage to provide for remote control by other pilot or 2-way valves. These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast.

  • A remote pilot relief on port 3 (vent) will control the valve below its own setting.
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. If used in cross port relief circuits, consider spool leakage.
  • Main stage orifice is protected by a 150-micron stainless steel screen.
  • Not suitable for use in load holding applications due to spool leakage.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.