Tryckbegränsningsventil SUN T-8A 10 l/min 1,7-210bar

Two-port, pilot-stage, direct-acting relief cartridges are fully adjustable, normally closed pressure regulating valves. When the pressure at port 1 (inlet) is sufficient to overcome the spring force (valve setting), a flow path is opened from port 1 to port 2 (tank).

  • Utilizes the Sun T-8A 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage pilot or vent-to-operate cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-position, 2-way pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
  • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • Ports 1 and 2 may be pressured to 350 bar.
  • Hardened poppet and seat provide consistent operation, low leakage rates and superior wear characteristics.
  • Backpressure at port 2 (outlet) is directly additive to the pressure setting at port 1 (inlet).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Varenummer:
RBAE-LAN

Pakke str.:
1 st

Min. bestillingsenhed er:
1 st
Cavity
T-8A

Flow Nominel
10 lpm

Forureningsgrad maks.
19/17/14 - ISO 4406

Materiale
Steel

Mærke navn
Sun Hydraulics

Olieviskositet anbefalet
2,8 - 380 cSt

Pakningsmateriale
NBR

Temperatur maks.
+110 °C

Temperatur min.
-30 °C

Tilspændingsmoment
27 - 33 Nm

Tryk maks.
350 bar

Trykindstilling maks.
210 bar

Trykindstilling min.
1.7 bar
Package size
1 st

Barcode
331631

Gross weight
Kg

Net weight
Kg

Country of origin
usa

Two-port, pilot-stage, direct-acting relief cartridges are fully adjustable, normally closed pressure regulating valves. When the pressure at port 1 (inlet) is sufficient to overcome the spring force (valve setting), a flow path is opened from port 1 to port 2 (tank).

  • Utilizes the Sun T-8A 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage pilot or vent-to-operate cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-position, 2-way pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
  • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • Ports 1 and 2 may be pressured to 350 bar.
  • Hardened poppet and seat provide consistent operation, low leakage rates and superior wear characteristics.
  • Backpressure at port 2 (outlet) is directly additive to the pressure setting at port 1 (inlet).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.