Prio. Valve 95l/m fixed flow 32l/m CP311-1-B-12S-8.0

This is a fixed, priority type, pressure compensated flow control valve, where the flow from port 3 will remain constant regardless of the pressure difference across the valve, while excess flow passes from port 1 to 2.

Flow enters at port 1 and passes across a fixed orifice in the spool, which creates a pressure drop. This causes the spool to move back against the spring, which then restricts the outlet flow. Port 1 then opens to port 2 to allow excess flow to pass. The regulated flow will always take priority and remains constant if the working pressure is higher in either port 2 or port 3.

Artikelnummer:
132278-CP311

Förpackningsstorlek:
1 st

Minsta beställningskvantitet:
1 st
Flow min. reglerat
32 lpm

Flöde in max.
95 lpm

Flöde max. reglerat
32 l/min

Föroreningsgrad max.
20/18/14 - ISO 4406

Kavitet
CP12-3

Modell kod
CP311-1-B-12S-8.0

Märke namn
Danfoss

Oljeviskositet rekommanderad
12 - 54 cSt

Packningsmaterial
NBR

Temperatur max.
+100 °C

Temperatur min.
-40 °C

Tryck max.
210 bar

Tryckkompenserad
Yes

antal vägar
3

Åtdragning moment
68 - 75 Nm
Förpackningsstorlek
1 st

Streckkod
379557

Bruttovikt
0,28 Kg

Nettovikt
0,28 Kg

Ursprungsland
ITA

Intrastat artikelkod
84812010

This is a fixed, priority type, pressure compensated flow control valve, where the flow from port 3 will remain constant regardless of the pressure difference across the valve, while excess flow passes from port 1 to 2.

Flow enters at port 1 and passes across a fixed orifice in the spool, which creates a pressure drop. This causes the spool to move back against the spring, which then restricts the outlet flow. Port 1 then opens to port 2 to allow excess flow to pass. The regulated flow will always take priority and remains constant if the working pressure is higher in either port 2 or port 3.