SOLENOID VALVE SV10-22-02-00-00-B-00

This is a 2-way, 2-position, spool type, normally closed solenoid valve. In its de-energized condition fl­ow is blocked in both directions. When energized, fl­ow can take place from port 2 to 1 and from 1 to 2. The valve will be subject to normal spool leakage dependent on the pressure difference between the ports.

These valves can be used to interrupt a pressure line where fl­ow is expected to pass in both directions in the de-energized condition.

Artikelnummer:
805313919

Förpackningsstorlek:
0 pcs

Minsta beställningskvantitet:
1 pcs
Mix-N-Match Dual Cross Body 1/2"DCP10-2-4B
Artikelnummer: 11135684
Mix-N-Match Dual Parallel Body 1/2"DPL10-2-4B
Artikelnummer: 11137221
Ventilhus Comatrol SDC10-2-S3B steel 3/8
Artikelnummer: 11143048
Housing SDC10-2-S4B steel 1/2 port
Artikelnummer: 11143049
COIL, EVH-EDH 06 48V DC M16--48D-26W-DN
Artikelnummer: 171112119
Spole M16-12D-26W-DN
Artikelnummer: 17114581
Coil M16-20D-27W-DN
Artikelnummer: 171145919
SEAL KIT SDC 10-2 B-2H #
Artikelnummer: 354004019
Activation
Solenoid

Brand Name
Danfoss

Cavity
SDC10-2

Contamination level max.
20/18/14 - ISO 4406

Filter built-in
No

Flow rate nominal LMin
35 lpm

Manual operated
No

Model code
SV10-22-02-00-00-B-00

Number of ways/positions
2/2

Oil viscocity recommended
12 - 54 cSt

Pressure max.
230 bar

Sealing material
NBR

Solenoidtype
M16

Temperature max.
+100 °C

Temperature min.
-40 °C

Torque tightening
45 - 50 Nm

Valve type
NC - Normally closed
Förpackningsstorlek
0 pcs

Streckkod
5704334372448

Bruttovikt
0,20 Kg

Nettovikt
0,20 Kg

Ursprungsland

Intrastat artikelkod
84812010

This is a 2-way, 2-position, spool type, normally closed solenoid valve. In its de-energized condition fl­ow is blocked in both directions. When energized, fl­ow can take place from port 2 to 1 and from 1 to 2. The valve will be subject to normal spool leakage dependent on the pressure difference between the ports.

These valves can be used to interrupt a pressure line where fl­ow is expected to pass in both directions in the de-energized condition.