PVEH proportional module - HIGH.
Similar to PVEA - but with fast reaction time.
Characteristic properties of PVEA:
- Inductive transducer,
- Integrated pulse width modulation,
- Hirschmann or AMP plug connection,
- Optionally with direction indicator (DI),
- Error monitoring with transistor output for signal generator,
- Low electrical power consumption,
- No setup procedure.
Active error monitoring: - Delay of over 500 ms (PVEA: 750 ms) before something happens. - The solenoid valve is reset and all valves are released. - An alarm signal is sent to the appropriate pin in the plug connection. - The fault condition is remembered and continues until the system is actively reset by disconnecting the supply voltage.
Passive error monitoring: - Delay of 250 ms (PVEA: 750 ms) before something happens. - The solenoid valve does not reset, but still controls the position of the main slider. - An alarm signal is sent to the appropriate pin in the plug connection. - The error state is not remembered. When the error condition disappears, the alarm signal becomes passive again. However, the signal remains active for a minimum of 100 ms when activated.