Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Suitable for use in load holding applications.
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Artikelnummer:
SCCA-LAN

Förpackningsstorlek:
1 st

Minsta beställningskvantitet:
1 st
Flödeshastighet nominell LMin
60 lpm

Föroreningsgrad max.
19/17/14 - ISO 4406

Kavitet
T-11A

Modell kod
SCCALAN

Märke namn
Sun Hydraulics

Oljeviskositet rekommanderad
2,8 - 380 cSt

Packningsmaterial
NBR

Temperatur max.
+110 °C

Temperatur min.
-30 °C

Tillverkningsmaterial
Steel

Tryck max.
350 bar

Tryckinställning max.
210 bar

Tryckinställning min.
35 bar

Åtdragning moment
41 - 47 Nm
Förpackningsstorlek
1 st

Streckkod
238042

Bruttovikt
0,22 Kg

Nettovikt
0,22 Kg

Ursprungsland

Intrastat artikelkod
84812010

Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Suitable for use in load holding applications.
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.