Sequence valve with check valve 35-210 bar - 60 l/min

Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Suitable for use in load holding applications.
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Partnumber:
SCCA-LAN

Package size:
1 pcs

Min. order quantity is:
1 pcs
Kiristysmomentti
41 - 47 Nm

Lämpötila max.
+110 °C

Lämpötila min.
-30 °C

Mallikoodi
SCCALAN

Materiaali
Steel

Paine max.
350 bar

Paineen asetus max.
210 bar

Paineen asetus min.
35 bar

Poraus
T-11A

Puhtaustaso min.
19/17/14 - ISO 4406

Tiivistysmateriaali
NBR

Tilavuusvirta nimellinen l/min
60 lpm

Tuotemerkit
Sun Hydraulics

Öljyn viskositeetti suositus
2,8 - 380 cSt
Package size
1 pcs

Barcode
238042

Gross weight
0,22 Kg

Net weight
0,22 Kg

Country of origin

Intrastat code
84812010

Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).

  • Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 350 bar.
  • Suitable for use in load holding applications.
  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).