Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. 1,7 bar check unless actuator cavitation is a concern.
  • This valve does not have positive seals on the pilot section and will pass between 0,03 and 0,3 L/min./70 bar between port 2 and port 3, depending on load pressure. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Varenummer:
CBCH-LJN

Pakke str.:
0 pcs

Min. bestillingsenhed er:
1 pcs
EAU - Sun hus T11A R3/8
Varenummer: EAU
Sun Block T11A 1/2
Varenummer: EAV
Ventilhus SUN T-11A NG6
Varenummer: EBA/M
Sun sandwich valve Block cetop
Varenummer: EBY
Ventilhus SUN T-11A x2 NG6 Stål
Varenummer: EBY/S
Sun Block T11A
Varenummer: ECT
Sun Block T11A steel
Varenummer: ECT/S
Sun Block T11A 3/8
Varenummer: ECU
Sun steel Block T11A 3/8
Varenummer: ECU/S
Sun valve block T11A R1/2 steel
Varenummer: ECV/S
Ventilhus SUN T-11A G1/4''
Varenummer: EFT
Ventilhus SUN T-11A G3/8'' Stål
Varenummer: EJU/S
X4B/S - Sun ventilhus T-11A Stål
Varenummer: X4B/S
Sun Block 2 x T11A 3/8
Varenummer: YEU
Sun Housing T-11A R3/8
Varenummer: YEU/S
Sun Block 2 x T11A 1/2
Varenummer: YEV
990-011-006 - Pakningssæt SUN T11-A Viton
Varenummer: 990-011-006
990-011-007 - Pakningssæt t/Sun ventil T11A Buna
Varenummer: 990-011-007
Cavity
T-11A

Flow Nominel
60 lpm

Forureningsgrad maks.
19/17/14 - ISO 4406

Materiale
Steel

Mærke navn
Sun Hydraulics

Olieviskositet anbefalet
2,8 - 380 cSt

Pakningsmateriale
NBR

Pilotforhold
10:1

Temperatur maks.
+110 °C

Temperatur min.
-30 °C

Tilspændingsmoment
41 - 47 Nm

Tryk maks.
350 bar

Trykindstilling maks.
350 bar

Trykindstilling min.
140 bar
Pakke str.
0 pcs

Stregkode
5704334192527

Brutto vægt
0,17 Kg

Netto vægt
0,17 Kg

Oprindelsesland

Intrastat varekode
84812010

10:1 pilot ratio, standard capacity counterbalance valve

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. 1,7 bar check unless actuator cavitation is a concern.
  • This valve does not have positive seals on the pilot section and will pass between 0,03 and 0,3 L/min./70 bar between port 2 and port 3, depending on load pressure. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.