Sun load control valve 10:1

10:1 pilot ratio, standard capacity counterbalance valve

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. 1,7 bar check unless actuator cavitation is a concern.
  • This valve does not have positive seals on the pilot section and will pass between 0,03 and 0,3 L/min./70 bar between port 2 and port 3, depending on load pressure. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Partnumber:
CBCH-LCN

Package size:
0 pcs

Min. order quantity is:
1 pcs
Ventilhus SUN T-11A 90gr
Partnumber: EAU
Ventilhus SUN T-11A G3/8'' Stål
Partnumber: EAU/S
Ventilhus SUN T-11A 90gr
Partnumber: EAV
Ventilhus SUN T-11A NG6
Partnumber: EBA
Ventilhus SUN T-11A NG6
Partnumber: EBA/M
Sun hus T11A
Partnumber: ECT
Ventilhus SUN T-11A G1/4'' Stål
Partnumber: ECT/S
Ventilhus SUN T-11A G3/8
Partnumber: ECU
Ventilhus SUN T-11A G3/8'' Stål
Partnumber: ECU/S
Ventilhus SUN T-11A G1/2
Partnumber: ECV
Ventilhus SUN T-11A G1/2'' stål
Partnumber: ECV/S
Ventilhus SUN T-11A G1/4''
Partnumber: EFT
Ventilhus SUN T-11A G3/8'' Stål
Partnumber: EJU/S
Sun valve block T-11A Steel
Partnumber: X4B/S
Ventilhus SUN T-11A dubbel
Partnumber: YEU
Ventilhus SUN T-11A dubbel stål
Partnumber: YEU/S
Sun Block 2 x T11A 1/2
Partnumber: YEV
P-sats SUN T11-A, Viton
Partnumber: 990-011-006
P-sats SUN T-11A Nitril
Partnumber: 990-011-007
Flödeshastighet nominell LMin
60 lpm

Föroreningsgrad max.
19/17/14 - ISO 4406

Kavitet
T-11A

Modell kod
CBCHLCN

Märke namn
Sun Hydraulics

Oljeviskositet rekommanderad
2,8 - 380 cSt

Packningsmaterial
NBR

Pilot förhållande
10:1

Temperatur max.
+110 °C

Temperatur min.
-30 °C

Tillverkningsmaterial
Steel

Tryck max.
350 bar

Tryckinställning max.
350 bar

Tryckinställning min.
140 bar

Åtdragning moment
41 - 47 Nm
Package size
0 pcs

Barcode
5704295236995

Gross weight
0,17 Kg

Net weight
0,17 Kg

Country of origin

Intrastat code
84812010

10:1 pilot ratio, standard capacity counterbalance valve

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. 1,7 bar check unless actuator cavitation is a concern.
  • This valve does not have positive seals on the pilot section and will pass between 0,03 and 0,3 L/min./70 bar between port 2 and port 3, depending on load pressure. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.