SOLENOID VALVE POPPET TYPE EVK EVK 06/C5-12D-A-DG-1/2

This is a 2-way, 2-position, poppet type, direct acting, normally closed, bi-directional solenoid valve. In its de-energized condition, fl­ow is blocked in both directions. Leakage in either direction is kept to a minimum due to the poppet design. When energized, ­flow can take place from port 2 to 1 and from 1 to 2.

These valves come standard with a push pin manual override. These valves can be used to hold loads in position or interrupt a pressure line where fl­ow is expected to pass in both directions in the de-energized condition. They do not suffer from momentary opening due to shock pressures.

Artikelnummer:
805349419

Förpackningsstorlek:
0 pcs

Minsta beställningskvantitet:
1 pcs
Sensor-/actuator cable - SAC-3P- 3.0-PUR/A-1L-Z
Partnumber: 1434992
COIL, EVH-EDH 06 48V DC M16--48D-26W-DN
Partnumber: 171112119
Coil M16-20D-27W-DN
Partnumber: 171145919
Spole M16-24D-26W-DN
Partnumber: 171146019
Spole M16-110RA-22W-DN
Partnumber: 171184319
Spole M16-220RA-22W-DN
Partnumber: 171184419
COIL, M16-12D-26W-DN M16-12D-26W-DN
Partnumber: 17114581
LINE BODY, NCS 06/2 DG 1/2 NCS06/2-DG 1/2
Partnumber: 922500513
Activation
Solenoid

Brand Name
Danfoss

Contamination level max.
20/18/14 - ISO 4406

Current type
DC

Flow rate nominal LMin
50 lpm

Material
Aluminium

Model code
EVK06/C5-12D-A-DG-1/2

Number of ways/positions
2/2

Oil viscocity recommended
12 - 54 cSt

Plug type
DIN 43650 Form A

Pressure max.
210 bar

Sealing material
NBR

Temperature max.
+100 °C

Temperature min.
-40 °C

Thread
G 1/2 BSP

Voltage
12 V
Package size
0 pcs

Barcode
5704334372592

Gross weight
0,71 Kg

Net weight
0,71 Kg

Country of origin

Intrastat code
84812010

This is a 2-way, 2-position, poppet type, direct acting, normally closed, bi-directional solenoid valve. In its de-energized condition, fl­ow is blocked in both directions. Leakage in either direction is kept to a minimum due to the poppet design. When energized, ­flow can take place from port 2 to 1 and from 1 to 2.