C.B. Valve 20l/m 69-207bar CP448-1-B-0-E-B-XXX-4.5-040

Overcenter Valve, Standard, Direct Acting, Internal Drain, Port 3 Pilot

This is a direct acting overcenter valve, which is a pilot assisted relief with a free flow check. With the relief valve set at approximately 1.3 times the maximum load induced pressure, the valve will prevent flow from port 1 to 2. When pilot pressure is applied to port 3, the valve will meter the flow from port 1 to 2, compensating for any change in pilot pressure due to over-running or unstable loads. Free flow takes place from port 2 to port 1 through the check portion of the valve.

These valves are ideal in most applications bringing stability, load holding, and hose failure protection when the valve is mounted onto or into the actuator. The spring chamber is connected to the valve port 2, so any back pressure will increase the pilot pressure required to keep the valve open and the pressure at which the valve will open as a relief valve.

Varenummer:
134507.000

Pakke str.:
0 pcs

Min. bestillingsenhed er:
1 pcs
KIT, SEAL (BUNA-N) #
Varenummer: 120238
Brand Name
Danfoss

Cavity
CP08-3L

Contamination level max.
20/18/14 - ISO 4406

Flow rate nominal LMin
20 lpm

Model code
CP448-1-B-0-E-B-XXX-4.5-040

Oil viscocity recommended
12 - 54 cSt

Pilot ratio
4,5:1

Pressure max.
350 bar

Pressure setting max.
350 bar

Pressure setting min.
103 bar

Sealing material
NBR

Torque tightening
34 - 41 Nm
Pakke str.
0 pcs

Stregkode
5704334467588

Brutto vægt
0,16 Kg

Netto vægt
0,16 Kg

Oprindelsesland
ITA

Intrastat varekode
84812010

Overcenter Valve, Standard, Direct Acting, Internal Drain, Port 3 Pilot

This is a direct acting overcenter valve, which is a pilot assisted relief with a free flow check. With the relief valve set at approximately 1.3 times the maximum load induced pressure, the valve will prevent flow from port 1 to 2. When pilot pressure is applied to port 3, the valve will meter the flow from port 1 to 2, compensating for any change in pilot pressure due to over-running or unstable loads. Free flow takes place from port 2 to port 1 through the check portion of the valve.

These valves are ideal in most applications bringing stability, load holding, and hose failure protection when the valve is mounted onto or into the actuator. The spring chamber is connected to the valve port 2, so any back pressure will increase the pilot pressure required to keep the valve open and the pressure at which the valve will open as a relief valve.