Sun pilot operated check valve

This valve is a pilot to open check valve. It has a non-sealed pilot, a steel seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction.

Pressure at the pilot (port 3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

Varenummer:
CKCB-XCN

Pakke str.:
0 pcs

Min. bestillingsenhed er:
1 pcs
Sun Block T11A 3/8
Varenummer: EAU
Sun Block T11A 1/2
Varenummer: EAV
Ventilhus SUN T-11A NG6
Varenummer: EBA/M
Sun sandwich valve Block cetop
Varenummer: EBY
Ventilhus SUN T-11A x2 NG6 Stål
Varenummer: EBY/S
Sun Block T11A
Varenummer: ECT
Sun Block T11A steel
Varenummer: ECT/S
Sun Block T11A 3/8
Varenummer: ECU
Sun steel Block T11A 3/8
Varenummer: ECU/S
Sun valve block T11A R1/2 steel
Varenummer: ECV/S
Ventilhus SUN T-11A G1/4''
Varenummer: EFT
EJU/S - Ventilhus SUN T-11A G3/8'' Stål
Varenummer: EJU/S
X4B/S - Sun ventilhus T-11A Stål
Varenummer: X4B/S
YEV - Sun hus 2 x T11A R1/2
Varenummer: YEV
Brand Name
Sun Hydraulics

Cavity
T-11A

Contamination level max.
19/17/14 - ISO 4406

Flow rate nominal LMin
60 lpm

Material
Steel

Model code
CKCBXCN

Oil viscocity recommended
2,8 - 380 cSt

Pilot ratio
3:1

Pressure max.
350 bar

Pressure opening
2 bar

Sealing material
NBR

Temperature max.
+110 °C

Temperature min.
-30 °C

Torque tightening
41 - 47 Nm

Valve type
Pilot to open checkvalve
Pakke str.
0 pcs

Stregkode
5704295372426

Brutto vægt
0,14 Kg

Netto vægt
0,14 Kg

Oprindelsesland

Intrastat varekode
84812010

This valve is a pilot to open check valve. It has a non-sealed pilot, a steel seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction.

Pressure at the pilot (port 3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.

Bemærk: Åbning af 3D-filer kræver et program der understøtter fil-formatet