Counter balance 115l/m CP441-1-V-0-E-B-XXX-4.5-015

CP441-1, Hydraulic Vent Valve

Operation

This 3-ported, externally piloted unit is a 12-size cartridge style, low leakage counterbalance valve with hydraulic vent. The check section allows free flow from the directional valve (port 2) to the load (port 1), while normally blocking flow from port 1 to port 2. Reverse flow is blocked until pilot pressure is applied at port 3. When the load pressure at port 1 rises above the pressure setting, the integral relief valve is activated, and pressure is relieved from port 1 to port 2.

 

Applications

Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center.

Partnumber:
132786

Package size:
0 pcs

Min. order quantity is:
1 pcs
Ventilhus till Orbital Motor MM-OMH-00-CP441-1-4B
Partnumber: 11026316
Ventilhus till Orbital Motor MM-OMS-00-CP441-1-4B
Partnumber: 11026318
Ventilblok f. Orbit Motor MM-OMH-LS-CP441-1-4B
Partnumber: 11026332
Ventilhus till Orbital Motor MM-OMS-LS-CP441-1-4B
Partnumber: 11026336
Valve Housing f.Orbital Motor MM-OMT-LS-CP441-1-6B
Partnumber: 11026338
Body DCB12-3S S6B Steel
Partnumber: 11118238
Flödeshastighet nominell LMin
115 lpm

Föroreningsgrad max.
20/18/14 - ISO 4406

Kavitet
CP12-3S

Modell kod
CP441-1-V-0-E-B-XXX-4.5-015

Märke namn
Danfoss

Oljeviskositet rekommanderad
12 - 54 cSt

Pilot förhållande
4,5:1

Tryck max.
350 bar

Tryckinställning max.
103 bar

Tryckinställning min.
103 bar

Åtdragning moment
68 - 75 Nm
Package size
0 pcs

Barcode
5704334410584

Gross weight
0,63 Kg

Net weight
0,63 Kg

Country of origin

Intrastat code
84812010

CP441-1, Hydraulic Vent Valve

Operation

This 3-ported, externally piloted unit is a 12-size cartridge style, low leakage counterbalance valve with hydraulic vent. The check section allows free flow from the directional valve (port 2) to the load (port 1), while normally blocking flow from port 1 to port 2. Reverse flow is blocked until pilot pressure is applied at port 3. When the load pressure at port 1 rises above the pressure setting, the integral relief valve is activated, and pressure is relieved from port 1 to port 2.

 

Applications

Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center.