C.B. Valve 60l/m 55-80bar 4.5:1 CB10-HV-1-B-1-F-55-B-00(TN)

CB10-HV, Hydraulic Vent Valve.

Operation

CB10-HV: Counterbalance valve, 10-size, hydraulic vent. This valve is 3-ported, externally piloted and low leakage. The check section allows free flow from the directional valve (port 2) to the load (port 1), while normally blocking flow from port 1 to port 2. Reverse flow is blocked until pilot pressure is applied at port 3. When the load pressure at port 1 rises above the pressure setting, the integral relief valve is activated, and pressure is relieved from port 1 to port 2.

 

Applications

Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center.

Partnumber:
11107233

Package size:
0 pcs

Min. order quantity is:
1 pcs
Ventilblok f. Orbit Motor MM-DH/DS-LS-CB10-4B
Partnumber: 11026320
Ventilblok f. Orbit Motor MM-OMP/OMR/WP/WR-LS-CB10-4B
Partnumber: 11026334
HOUSING, SDC10-3S-SE3B (3/8) SDC10-3S--SE3B
Partnumber: 922517310
HOUSING, SDC10-3S-SE4B (1/2) SDC10-3S--SE4B
Partnumber: 922517410
HOUSING, DCB10-3S-SE-3B DCB10-3S--SE-3B
Partnumber: 922518510
HOUSING, DCB10-3S-SE-4B DCB10-3S--SE-4B
Partnumber: 922518610
Housing SDC10-3S-SES3B Steel
Partnumber: 922519010
Ventilhus SDC10-3S-SE4B 1/2 Stål
Partnumber: 922519410
Pakningssæt CB 10
Partnumber: 230001020
Cavity
SDC10-3S

Flow Nominel
60 lpm

Forureningsgrad maks.
20/18/14 - ISO 4406

Model kode
CB10-HV-1-B-1-F-55-B-0

Mærke navn
Danfoss

Olieviskositet anbefalet
12 - 54 cSt

Pakningsmateriale
NBR

Pilotforhold
4,5:1

Tilspændingsmoment
45 - 50 Nm

Tryk maks.
350 bar

Trykindstilling maks.
55 bar
Package size
0 pcs

Barcode
5704334467199

Gross weight
Kg

Net weight
Kg

Country of origin
ITA

Intrastat code
84812010

CB10-HV, Hydraulic Vent Valve.

Operation

CB10-HV: Counterbalance valve, 10-size, hydraulic vent. This valve is 3-ported, externally piloted and low leakage. The check section allows free flow from the directional valve (port 2) to the load (port 1), while normally blocking flow from port 1 to port 2. Reverse flow is blocked until pilot pressure is applied at port 3. When the load pressure at port 1 rises above the pressure setting, the integral relief valve is activated, and pressure is relieved from port 1 to port 2.

 

Applications

Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center.